Encoder's output type, output circuit and wave

Output signal type Coder Output circuit Wave
Open collector
output
C When resister connected between
output and external high level, output
wave is the same as push-pull output
C2=PNP open collector
C=NPN open collector
Push-pull F
Voltage E
Line drive output D
L
P
M
H
UVW output for
detecting AC motor
AC

Encoder electrical parameters

Model Output type Power
supply(V)
Current
Consumption(MA)
Output voltage Injection
Current(MA)
Mim.load
Impedance(Ω)
Rise/fall
time(VS)
Max.response
VH VL
05C Open collector 5±0.25 ≤100
-
-
≤30
-
≤1 0~200
05E Voltage 5±0.25 ≤100 ≥3.5 ≤0.5
-
-
≤1 0~200
05F Push-pull 5±0.25 ≤100 ≥3.5 ≤0.5
-
-
≤1 0~200
05L Line driver 5±0.25 ≤100 ≥2.5 ≤0.5
-
-
≤0.2 0~200
05H Line driver 5±0.25 ≤100 ≥2.5 ≤0.5
-
-
≤0.2 0~200
05D Line driver 5±0.25 ≤100 ≥2.5 ≤0.5
-
-
≤0.2 0~200
05P Line driver 5±0.25 ≤100 ≥2.5 ≤0.5
-
-
≤0.2 0~200
12C Open collector 12±1.2 ≤100
-
-
≤30
-
≤1 0~200
12E Voltage 12±1.2 ≤100 ≥8.0 ≤0.5  
-
≤1 0~200
12F Push-pull 12±1.2 ≤100 ≥8.0 ≤0.5  
-
≤1 0~200
15C Open collector 15±1.5 ≤100     ≤30
-
≤1 0~200
15E Voltage 15±1.5 ≤100 ≥10.0 ≤0.5  
-
≤1 0~200
15F Push-pull 15±1.5 ≤100 ≥10.0 ≤0.5
-
≥500 ≤1 0~200
24C Open collector 24±2 ≤150     ≤30
-
≤2 0~200
24E Voltage 24±2 ≤150 ≥3.5 ≤0.5
-
-
≤2 0~200
24F Push-pull 24±2 ≤150 ≥20.0 ≤0.5   ≥500 ≤2 0~200
24M Line driver 24±2 ≤150 ≥18.0 ≤0.5
-
-
≤0.2 0~200

Common plug used for encoder
Code
Icon
Outline drawing
P
Y
J

Matters needing attention of the encoder for installation and use

Mechanism reated
The connection between encoder and the users output shaft should be used in soft connections , avoid the use of rigid connections.
Please note that the axil loading of permission should not exceed its loading limit.
Please don't exceed the limit of its electrical speed, such as, when it exceeds the speed of its permission, the electrical signal may be lost.
The installation of encoder should be lightly fitted into the shaft sleeve, and strictly forbid hitting by hammer, percussion and crashing, in order to avoid damaging shaft and perspex disk.

Electric related
The output cable of encoder and power cable can not be fixed together of putted in same tube. The output cable should also be far from the switchboard to avoid disturbing. The cable should be shielded.
Careful check should be taken before starting the machine, the product instruction should be matched with the encoder model, wire connection should be correct, wrong connection will damage the internal circuit
Signal degradation factor should be considered when taking a long distance transmission. The output mode should be with ow outpur resistance and strong anti-disturbing capacity.
The transmission distance for pulse signal is related with the following factors: frequency, output circuit, input circuit, transmission cable and trandmitting frequency.

Environmet related
The encoder is a precision apparatus, when use it, it should be far away from vibration source.
The encoder is not designed with sealed structure, prevent water or oil etc. Splashing on it. Use a protecthood if necessary.
The environmental temperature and humidity should be in the operation range.
Note: performance and service life of encoder will be affected seriously by improper.